Sign In | Join Free | My chinaqualitycrafts.com
China Xiamen Ai Power Technology Co., Ltd. logo
Xiamen Ai Power Technology Co., Ltd.
Active Member

4 Years

Home > Perkins Diesel Generator Set >

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder

Xiamen Ai Power Technology Co., Ltd.
Contact Now

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder

  • 1
  • 2
  • 3

Brand Name : Ai Power Perkins 45kva Generator Set

Model Number : A50

Certification : CE, ISO9001

Place of Origin : China

MOQ : 1 Unit

Price : USD 7000 to 8500 Per Unit Negotiable

Payment Terms : Western Union, L/C, T/T, MoneyGram

Supply Ability : 300 Units Per Month

Delivery Time : 30 Days

Packaging Details : Plywood Or Plastic Film

Prime Power : 45kva/36kw

Standby Power : 50kva/40kw

Perkins Engine Model : 1103A-33TG1

Cylinder : 3 vertical in-line

Displacement : 3.3 (201)

Aspiration : Turbocharged

Bore and stroke : 105 x 127 (4.1 x 5.0)

Combustion system : Direct injection

Rotation (viewed from flywheel) : Anti-clockwise, viewed from flywheel

Total lubricating oil capacity, litres (US gal) : 8.3 (2.2)

Contact Now

Prime Power 45kva 50kva 3 Cylinder In Line Turbocharged Perkins Generator Displacement

Features and benefits

.Compact, efficient power is achieved from the 3.3 cylinder block maintaining bore roundness under the pressures of operation. Combustion
and mechanical noise are also lowered, whilst the cylinder head delivers optimised air control.
. Compact size, low noise, lower fuel consumption and oil use and service intervals of 500 hours as standard deliver cost effective power.
. Quality by design and Class A manufacturing improvements enhance product reliability while maintaining Perkins reputation for durability.
.Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 and ordering systems, all dedicated to maximising the productivity of your engine

Output Ratings

Generator set model Voltage Hz Phase P.F. Prime Power Standby Power
(V) KVA KW KVA KW
AP33 230/400 50 3 0.8 50 40 55 44

Technical information

Circuit Breaker and Fuel Tank

Circuit Breaker capacity (A) 63
Battery Brand Varta
Base Fuel Tank Capacity (L) 58

Perkins Engine 1103A-33G Model Specification

Engine manufacture Perkins Engines Company Limited
Engine brand Perkins
Engine model 1103A-33TG1
Engine speed (rpm) 1500
Prime power Standby power
Gross engine power (kWb) 42.2 45.6
Typical Genset electrical output 0.8pf 25ºC (100 kPa) (KW) 36 39.7
Cylinders 3-cylinder, vertical in line
Cycle 4 stroke
Induction system Naturally Aspriated
Combustion system Direcct injection
Compression ratio 17.25:1
Bore * Stroke (mm) 105*127
Cubic capacity (Litre) 3.3

Perkins Diesel Generator Set 24KW/30KVA 404A-22G1 Photos

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder

FAQ:

Q: What oil should I use?

A: Recommendations vary for each engine type based on engine and operating temperature. Please consult your owner’s manual for oil recommendations.

Can I use synthetic oil?

Synthetic oils meeting the classifications listed in your owner's manual may be used; however, you should still perform oil changes at the recommended intervals.

How much oil goes in my engine?

Due to possible variations within a model series, we recommend that you rely on your actual dipstick readings. Add oil of the proper type up to the "F" or "FULL" mark on the dipstick. Your owner's manual can provide you with more specific information.

Can I use additives in my engine?

We do not recommend using additives or cleaners in the oil or fuel system. Air-cooled engines operate at higher temperatures than liquid-cooled automotive engines, and additives developed for automotive use may not perform properly at higher temperatures.
In addition, oil additives can prematurely break down, altering the properties of the oil and leading to extensive internal damage or failure. Fuel system cleaning additives have a tendency to separate and turn acidic, causing damage to fuel system components. We do, however, recommend a fuel stabilizer during periods of non-use (one month or more) to retard fuel deterioration.

More information Feel free to contact me:

Email: nancy@aipowergen.com,

whatsapp/wechat: 0086 13906008114.

MS Nancy


Product Tags:

45 kva Perkins Diesel Generator Set

      

50 kva Perkins Diesel Generator Set

      

three phase diesel generator 44kw

      
Quality Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder for sale

Three Phase 45kva 50 Kva Perkins Diesel Generator Set 44kw 3 Cylinder Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xiamen Ai Power Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)